Analysis of temperature on the surface of the wrist due to repetitive movements using sensory thermography
Related Experiment Video
Updated: May 25, 2026

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
C Camargo1, J Ordorica, E J De la Vega
1Department of Industrial Engineering, Faculty of Engineering, Architecture and Design, Autonomous University of Baja California, Km. 103 Tijuana-Ensenada highway w/n. Ensenada, Baja California, Mexico. ccamargo@uabc.edu.mx
Unlabelled:
This study examines changes in body temperature generated in the wrist area through sensory thermography technique because of highly repetitive movements, proving with this technique that there is a decreased ability to perform muscular work, and thereby assess possible pathologies of Cumulative Trauma Disorders (CTDs).
Methods:
Two healthy right-handed individuals, who performed repetitive work, emulating an operation of the textile industry for three days, generated DTA in the area of the wrist. The evaluation time was of 3 hours 30 minutes in a controlled temperature between 20 and 25°C, 20 minutes stabilization time at the beginning and end of the operation.
Results:
The maximum temperatures reached were on the right wrist (RW) of 35. 078°C over a period of 1 hour 41 minutes 52 seconds; and on the left wrist (LR), 34.663°C over a period of 2 hours 42 minutes 51 seconds, detected discomfort in their right shoulder and wrist in the time range which identified the highest temperatures. It was shown that the data does not fit a normal distribution for RW and LW; the data fit the three- parameters Weibull distribution for WR and LW with a correlation coefficient between 0.93 to 0.99.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Thermosensation
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...