Related Experiment Video
Updated: May 25, 2026

Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Development of a screening method for the determination of PCBs in water using QuEChERS extraction and gas
Jia-Wei Shi1, Yong-Gang Zhao, Zhen-Jun Fu
1Ningbo Key Laboratory of Poison Research and Control, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China.
Abstract:
A new method has been developed and validated for the simultaneous analysis of 11 polychlorinated biphenyls (PCBs), in water samples at trace levels by gas chromatography coupled to triple quadrupole mass spectrometry (GC-QqQ-MS/MS). Water samples were extracted by the QuEChERS (Quick Easy Cheap Effective Rugged and Safe) method. The QqQ analyzer acquired data in multiple reactions monitoring (MRM), permitting both quantification and confirmation in a single injection with a running time reduced up to 11.0 min. The effect of matrix interferences in extracts on analyte quantification and the identification of PCBs in water samples was deeply studied. The results showed that PCBs were prone to strong matrix interactions in water samples, and the quantification and identification of PCBs were highly affected by a matrix enhancement effect. To evaluate the performance of the method, validation experiments were carried out on water samples at three spiking levels (1.6, 8.0, 40.0 µg L(-1)). Recovery was in the range of 95 - 109% at 1.6 µg L(-1), 90 - 95% at 8.0 µg L(-1) and 97 - 102% at 40.0 µg L(-1), respectively. Precision values expressed as relative standard deviation (RSD) were lower than 15%. Linearity in the range of 0.5 - 50.0 µg L(-1) provided determination coefficients (R(2)) higher than 0.999 for all compounds. The limits of detection (LODs) for PCBs were ≤0.1 µg L(-1) and the limits of quantification (LOQs) ranged from 0.04 to 0.3 µg L(-1). The applicability of the proposed method to detect and quantify PCBs has been demonstrated in analyse of 15 real samples.
More Related Videos
05:20Determination of 45 Pesticides in Avocado Varieties by the QuEChERS Method and Gas Chromatography-Tandem Mass Spectrometry
Published on: December 8, 2023
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II