Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Rapidly Varying Flow01:24

Rapidly Varying Flow

Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
Bioreactor Controls-II01:18

Bioreactor Controls-II

In aerobic fermentations, oxygen is vital for microbial growth and metabolite production. Since air comprises only about 20% oxygen and the gas is poorly soluble in water—just 9 ppm at 20°C—supplying sufficient oxygen becomes a critical challenge, especially in high-demand processes like yeast growth or citric acid production. Even a fully saturated broth may offer only a few seconds of oxygen availability.To address this, sterile or scrubbed air is introduced into the fermentor via a sparger...
Steady, Laminar Flow Between Parallel Plates01:17

Steady, Laminar Flow Between Parallel Plates

Understanding steady, laminar flow between parallel plates is essential for analyzing and designing flow in narrow rectangular channels, commonly found in various water conveyance and drainage systems. The Navier-Stokes equations govern fluid motion and are generally challenging to solve due to their nonlinearity. However, simplifications are possible in certain cases, like the steady laminar flow between parallel plates. For this scenario, we assume steady, incompressible, laminar flow.
Pipe Flowrate Measurement01:28

Pipe Flowrate Measurement

In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
Steady, Laminar Flow in Circular Tubes01:23

Steady, Laminar Flow in Circular Tubes

Hagen-Poiseuille flow describes a viscous fluid's steady, incompressible flow through a cylindrical tube with a constant radius R. This flow profile is often applied to understand fluid transport in narrow channels, such as capillaries. It serves as a foundational example of laminar flow. In this model, cylindrical coordinates (r,θ,z) are used to describe the radial (r), angular (θ), and axial (z) dimensions within the tube. For Hagen-Poiseuille flow, the velocity profile is purely axial,...
Fast Reactions01:27

Fast Reactions

Fast reactions occurring in times shorter than the time needed to mix reactants pose a unique challenge for investigation. In a liquid-phase continuous-flow system, reactants A and B are swiftly pushed into the mixing chamber, where mixing occurs within 1 ms. The reaction mixture then flows through an observation tube, and one measures light absorption to determine species concentrations at various points of the tube. This method is most appropriate when relatively large volumes of reactants...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Do we need post-pregnancy screening with human chorionic gonadotrophin after previous hydatidiform mole to identify patients with recurrent gestational trophoblastic disease?

European journal of obstetrics, gynecology, and reproductive biology·2019
Same author

Gastric myoelectrical and neurohormonal changes associated with nausea during tilt-induced syncope.

Neurogastroenterology and motility·2017
Same author

Reduced levels of plasma kisspeptin during the antenatal booking visit are associated with increased risk of miscarriage.

The Journal of clinical endocrinology and metabolism·2014
Same author

Distribution-based sensitivity metric for highly variable biochemical systems.

IET systems biology·2011
Same author

Highlights on the X-ray diagnosis of cancer in the gastrointestinal tract.

The Illinois cancer bulletin·2010
Same author

THE ROENTGEN RADIATION OF PAPILLOMA VIRUS (SHOPE) : I. THE EFFECT OF X-RAYS UPON PAPILLOMAS ON DOMESTIC RABBITS.

The Journal of experimental medicine·2009
Same journal

The ACS at 150: The History of Analytical Chemistry Publications and a Century of Progress.

Analytical chemistry·2026
Same journal

Machine Learning-Enabled Image Analysis of Complex Chemical Mixtures: Synthetic Urine Droplets as a Test System.

Analytical chemistry·2026
Same journal

H<sub>2</sub>O<sub>2</sub>/Viscosity Tandem-Locked Fluorescent Probes Based on an In Situ Fluorophore Synthesis Strategy for Colitis Imaging and Diagnosis.

Analytical chemistry·2026
Same journal

TopoStitcher: A Geometric-Topological Structure-Guided Stitching Framework for Single-Molecule Localization Microscopy.

Analytical chemistry·2026
Same journal

Noninvasive SERS Immunosensing of Tyrosinase for Melanoma Monitoring via Microneedle Sampling Integrated with Satellite-Structured Bifunctional Nanozymes.

Analytical chemistry·2026
Same journal

Label-Free Electrochemical CRISPR Platform Gated by Allosteric Transcription Factors for Ultrasensitive Small-Molecule Detection.

Analytical chemistry·2026
See all related articles

Related Experiment Video

Updated: May 25, 2026

Bilayer Microfluidic Device for Combinatorial Plug Production
07:03

Bilayer Microfluidic Device for Combinatorial Plug Production

Published on: December 1, 2023

Variable-ratio stopped-flow mixing device

R A Harvey, W O Borcherdt

    Analytical Chemistry
    |February 14, 2012
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device
    14:48

    Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device

    Published on: April 17, 2021

    Related Experiment Videos

    Last Updated: May 25, 2026

    Bilayer Microfluidic Device for Combinatorial Plug Production
    07:03

    Bilayer Microfluidic Device for Combinatorial Plug Production

    Published on: December 1, 2023

    Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device
    14:48

    Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device

    Published on: April 17, 2021