Related Experiment Video
Updated: May 25, 2026

Two-dimensional Gel Electrophoresis Coupled with Mass Spectrometry Methods for an Analysis of Human Pituitary Adenoma Tissue Proteome
Published on: April 2, 2018
The utility of porous graphitic carbon as a stationary phase in proteomics workflows: two-dimensional chromatography
John R Griffiths1, Simon Perkins, Yvonne Connolly
1Paterson Institute for Cancer Research, University of Manchester, Wilmslow Road, Manchester, UK. jgriffiths@picr.man.ac.uk
Abstract:
We present the first investigation into the utility of porous graphitic carbon (PGC) as a stationary phase in proteomic workflows involving complex samples. PGC offers chemical and physical robustness and is capable of withstanding extremes of pH and higher temperatures than traditional stationary phases, without the likelihood of catastrophic failure. In addition, unlike separations driven by ion exchange mechanisms, there is no requirement for high levels of non-volatile salts such as potassium chloride in the elution buffers, which must be removed prior to LC-MS analysis. Here we present data which demonstrate that PGC affords excellent peptide separation in a complex whole cell lysate digest sample, with good orthogonality to a typical low pH reversed-phase system. As strong cation exchange (SCX) is currently the most popular first dimension for 2D peptide separations, we chose to compare the performance of a PGC and SCX separation as the first dimension in a comprehensive 2D-LC-MS/MS workflow. A significant increase, in the region of 40%, in peptide identifications is reported with off-line PGC fractionation compared to SCX. Around 14,000 unique peptides were identified at an estimated false discovery rate of 1% (n=3 replicates) from starting material constituting only 100 μg of protein extract.
More Related Videos
10:59Glycomics-Guided Glycoproteomics Facilitates Comprehensive Profiling of the Glycoproteome in Complex Tumor Microenvironments
Published on: February 7, 2025
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Ion-Exchange Chromatography
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Principles Of Column Chromatography
Electrophoresis: Overview
There...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.