Related Experiment Video
Updated: May 25, 2026

In vitro Functional Characterization of Mouse Colorectal Afferent Endings
Published on: January 21, 2015
High sensitivity recording of afferent nerve activity using ultra-compliant microchannel electrodes: an acute in vivo
Ivan R Minev1, Daniel J Chew, Evangelos Delivopoulos
1Nanoscience Centre, University of Cambridge, Cambridge CB3 0FF, UK. irm33@cam.ac.uk
Abstract:
Neuroprostheses interfaced with transected peripheral nerves are technological routes to control robotic limbs as well as convey sensory feedback to patients suffering from traumatic neural injuries or degenerative diseases. To maximize the wealth of data obtained in recordings, interfacing devices are required to have intrafascicular resolution and provide high signal-to-noise ratio (SNR) recordings. In this paper, we focus on a possible building block of a three-dimensional regenerative implant: a polydimethylsiloxane (PDMS) microchannel electrode capable of highly sensitive recordings in vivo. The PDMS 'micro-cuff' consists of a 3.5 mm long (100 µm × 70 µm cross section) microfluidic channel equipped with five evaporated Ti/Au/Ti electrodes of sub-100 nm thickness. Individual electrodes have average impedance of 640 ± 30 kΩ with a phase angle of -58 ± 1 degrees at 1 kHz and survive demanding mechanical handling such as twisting and bending. In proof-of-principle acute implantation experiments in rats, surgically teased afferent nerve strands from the L5 dorsal root were threaded through the microchannel. Tactile stimulation of the skin was reliably monitored with the three inner electrodes in the device, simultaneously recording signal amplitudes of up to 50 µV under saline immersion. The overall SNR was approximately 4. A small but consistent time lag between the signals arriving at the three electrodes was observed and yields a fibre conduction velocity of 30 m s(-1). The fidelity of the recordings was verified by placing the same nerve strand in oil and recording activity with hook electrodes. Our results show that PDMS microchannel electrodes open a promising technological path to 3D regenerative interfaces.
More Related Videos
09:35Fabrication of High Contact-Density, Flat-Interface Nerve Electrodes for Recording and Stimulation Applications
Published on: October 4, 2016
09:34Use of In Vivo Single-fiber Recording and Intact Dorsal Root Ganglion with Attached Sciatic Nerve to Examine the Mechanism of Conduction Failure
Published on: August 27, 2019