Behaviour of RO98pHt polyamide membrane in reverse osmosis and low reverse osmosis conditions for phenol removal

A M Hidalgo1, G León, M Gómez

  • 1Departamento de Ingeniería Química, Grupo de Análisis y Simulación de Procesos Químicos, Bioquímicos y de Membrana, Universidad de Murcia, Campus de Espinardo, 30071 Murcia, Spain. ahidalgo@um.es

Environmental Technology
|February 15, 2012
PubMed

Related Concept Videos

Osmosis and Osmotic Pressure of Solutions02:40

Osmosis and Osmotic Pressure of Solutions

A number of natural and synthetic materials exhibit selective permeation, meaning that only molecules or ions of a certain size, shape, polarity, charge, and so forth, are capable of passing through (permeating) the material. Biological cell membranes provide elegant examples of selective permeation in nature, while dialysis tubing used to remove metabolic wastes from blood is a more simplistic technological example. Regardless of how they may be fabricated, these materials are generally...
Hydrolysis of Chlorobenzene to Phenol: Dow Process01:10

Hydrolysis of Chlorobenzene to Phenol: Dow Process

Simple aryl halides do not react with nucleophiles under normal conditions. However, the reaction can proceed under drastic conditions involving high temperatures and high pressure to give the substituted products. For example, chlorobenzene is converted to phenol using aqueous sodium hydroxide at 350 °C under high pressure by the Dow process. The reaction follows an elimination-addition mechanism involving a benzyne intermediate. Here, the chloride ion is eliminated to generate the benzyne...
Osmotic Pressure01:26

Osmotic Pressure

Osmosis is a process where solvent molecules move toward a solution through a semipermeable membrane. As the solution dilutes due to the entry of solvent, it expands. This expansion increases the hydrostatic pressure of the solution. When the hydrostatic pressure equals the osmotic pressure, osmosis stops.Osmotic pressure, denoted by Π, is the minimum pressure needed to prevent the solvent from passing into the solution by osmosis. The van 't Hoff equation calculates the osmotic pressure of an...
Ion Exchange01:17

Ion Exchange

Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or basic...