Related Experiment Video
Updated: May 24, 2026

Correction of Presbyopia by Monocular Bi-Aspheric Ablation Profile
Published on: September 20, 2024
Argon laser iridoplasty to improve visual function following multifocal intraocular lens implantation
Renée Solomon1, Allon Barsam, Alex Voldman
1Ophthalmic Consultants of Long Island, Rockville Centre, New York, NY 10021, USA. rensight@yahoo.com
Purpose:
To describe the use of argon laser iridoplasty following implantation of a multifocal intraocular lens (IOL) to improve visual function.
Methods:
Argon laser spots of 500-mW power, 500-μm spot diameter, and 500-ms duration were placed in the midperipheral iris in the area in which the iris was encroaching on the IOL.
Results:
Argon laser iridoplasty provided statistically significant improvement in visual function including corrected distance visual acuity (CDVA) and subjective quality of vision in 14 eyes from 11 patients. Mean CDVA improved from 0.24 (20/35 Snellen) to 0.10 (20/25 Snellen) logMAR (P<.0001), and mean subjective quality of vision improved from 2.9 to 7.5 (P<.0001).
Conclusions:
Argon laser iridoplasty should be considered in correcting visual problems associated with decentered multifocal IOLs.
More Related Videos
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Focusing of Light in the Eye