Related Experiment Video
Updated: May 24, 2026

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Reliability and construct validity of the karate-specific aerobic test
Helmi Chaabène1, Younés Hachana, Emerson Franchini
1Research Unit, Analysis and Evaluation of Factors Affecting the Sport Performance, Higher Institute of Sports and Physical Education, Ksar said, Tunisia. chaabanehelmi@hotmail.fr
Abstract:
ABThe aim of this study was to examine absolute and relative reliabilities and external responsiveness of the Karate-specific aerobic test (KSAT). This study comprised 43 male karatekas, 19 of them participated in the first study to establish test-retest reliability and 40, selected on the bases of their karate experience and level of practice, participated in the second study to identify external responsiveness of the KSAT. The latter group was divided into 2 categories: national-level group (G(n)) and regional-level group (G(r)). Analysis showed excellent test-retest reliability of time to exhaustion (TE), with intraclass correlation coefficient ICC(3,1) >0.90, standard error of measurement (SEM) <5%: (3.2%) and mean difference (bias) ± the 95% limits of agreement: -9.5 ± 78.8 seconds. There was a significant difference between test-retest session in peak lactate concentration (Peak [La]) (9.12 ± 2.59 vs. 8.05 ± 2.67 mmol·L(-1); p < 0.05) but not in peak heart rate (HRpeak) and rating of perceived exertion (RPE) (196 ± 9 vs. 194 ± 9 b·min(-1) and 7.6 ± 0.93 vs. 7.8 ± 1.15; p > 0.05), respectively. National-level karate athletes (1,032 ± 101 seconds) were better than regional level (841 ± 134 seconds) on TE performance during KSAT (p < 0.001). Thus, KSAT provided good external responsiveness. The area under the receiver operator characteristics curve was >0.70 (0.86; confidence interval 95%: 0.72-0.95). Significant difference was detected in Peak [La] between national- (6.09 ± 1.78 mmol·L(-1)) and regional-level (8.48 ± 2.63 mmol·L(-1)) groups, but not in HRpeak (194 ± 8 vs. 195 ± 8 b·min(-1)) and RPE (7.57 ± 1.15 vs. 7.42 ± 1.1), respectively. The result of this study indicates that KSAT provides excellent absolute and relative reliabilities. The KSAT can effectively distinguish karate athletes of different competitive levels. Thus, the KSAT may be suitable for field assessment of aerobic fitness of karate practitioners.
Related Concept Videos
Reliability and Validity
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
