Related Experiment Video
Updated: May 24, 2026

Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
ICP-MS and LC-ICP-MS for analysis of trace element content and speciation in cereal grains
D P Persson1, T H Hansen, K H Laursen
1Plant and Soil Science Laboratory, Department of Agriculture and Ecology, The University of Copenhagen, Copenhagen, Denmark.
Abstract:
Trace elements are unevenly distributed and speciated throughout the cereal grain. The germ and the outer layers of the grain have the highest concentrations of trace elements. A large fraction of the trace elements is therefore lost during the milling process. The bioavailability of the remaining trace elements is very low. This is usually ascribed to the formation of poorly soluble complexes with the phosphorus storage compound phytic acid. Hence, analysis of the total concentration of trace elements in grain tissues must be combined with a speciation analysis in order to assess their contribution to human nutrition. This chapter deals with the fractionation of anatomically very different cereal tissues. Procedures for microscaling of digestion procedures are outlined together with requirements for the use of certified reference materials in elemental profiling of grain tissue fractions. Methods for extraction and analysis of complexes containing trace elements in the grain tissue fractions are described. Finally, the chapter concludes with criteria for choice of chromatographic methods and setting of ICP-MS instrument parameters.
More Related Videos
12:03Two-Dimensional Visualization and Quantification of Labile, Inorganic Plant Nutrients and Contaminants in Soil
Published on: September 1, 2020
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...