An Educational Video Demonstration of How to Prone a Critically Ill Intubated Patient
Published on: November 30, 2022
Double-lumen tube placement with the patient in the supine position without a headrest minimizes displacement during
Jeong-Hwa Seo1, Deok Man Hong, Jung-Man Lee
1Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, Korea.
Purpose:
The correct position of double-lumen tubes (DLTs) is customarily confirmed after tracheal intubation by bronchoscopy with the patient supine on a headrest. However, displacement of DLTs usually occurs during lateral positioning because of neck extension. This study was undertaken to determine whether displacement of DLTs could be minimized during lateral positioning if DLTs were positioned without a headrest.
Methods:
One hundred patients scheduled for thoracic surgery were randomized into two groups (n = 50 each). After tracheal intubation using a headrest, adjustment of DLT position was performed according to group assignment, i.e., either with the headrest in place or without the headrest. Using a bronchoscope, distances from the tracheal opening to the main carina and from the bronchial opening to the left bronchial carina were measured in both the supine and lateral positions.
Results:
Displacement of DLTs [mean (standard deviation)] during lateral positioning was greater in the headrest group than in the no-headrest group [12.3 (6.5) mm vs 6.8 (5.5) mm, respectively, in the trachea; 11.6 (6.7) mm vs 6.0 (4.6) mm, respectively, in the bronchus; P < 0.001]. The incidence of significant displacement, defined as > 10 mm from initial correct position, was greater in the headrest group than in the no-headrest group (64% vs 28%, respectively, in the trachea; 58% vs 20%, respectively, in the bronchus; P < 0.001).
Conclusion:
Displacement of DLTs during lateral positioning appears to be caused primarily by extension of the neck. Correct adjustment of DLT position without a headrest in the supine position is an easy and effective method to minimize DLT displacement during lateral positioning.
Related Concept Videos
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.