Development and Validation of a HPLC and an UV Spectrophotometric Methods for Determination of Dexibuprofen in

Selvadurai Muralidharan1, Subramania Nainar Meyyanathan

  • 1Department of Pharmaceutical Analysis, JSS College of Pharmacy, Ootacamund, Tamilnadu-643 001, India.

ISRN Pharmaceutics
|March 6, 2012
PubMed

Related Concept Videos

Clinically Relevant Drug Product Specifications: Methods of Establishment01:29

Clinically Relevant Drug Product Specifications: Methods of Establishment

Product specifications define the acceptable quality of a pharmaceutical product by ensuring identity, purity, potency, and strength. These specifications serve as benchmarks during development, manufacturing, and post-approval quality control. Clinically relevant specifications are particularly important because they directly relate to a drug's safety and efficacy in clinical use.Dissolution studies are critical biopharmaceutic tools that link in vitro behavior to in vivo performance. They...
Protein-Drug Binding: Determination Methods01:22

Protein-Drug Binding: Determination Methods

Determining protein-drug binding can be achieved through indirect and direct methods, each providing valuable insights into the interaction between proteins and drugs.
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Therapeutic Drug Monitoring: Drug Analysis Methods01:26

Therapeutic Drug Monitoring: Drug Analysis Methods

Therapeutic Drug Monitoring (TDM) is a clinical practice that measures specific drug levels in a patient's blood or body tissues to tailor drug therapy effectively. This monitoring is critical for managing drugs with narrow therapeutic indices like digoxin and phenytoin, ensuring they are both safe and effective. For instance, monitoring theophylline levels in asthma patients involves precision and sensitivity to adjust doses according to individual responses to therapy, ensuring efficacy and...
Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
Measurement of Bioavailability: Pharmacokinetic Methods01:30

Measurement of Bioavailability: Pharmacokinetic Methods

Pharmacokinetics is a vital branch of pharmacology that examines how drugs are absorbed, distributed, metabolized, and excreted by the body. Two key methodologies in pharmacokinetics are plasma drug concentration studies and urinary drug excretion analyses, both of which provide critical insights into a drug's therapeutic efficacy and bioavailability.Plasma Drug Concentration-Time StudiesPlasma drug concentration-time studies involve analyzing blood samples at specific intervals to quantify...