Related Experiment Video
Updated: May 24, 2026

Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
Published on: December 14, 2020
A new evaluation of the upper esophageal sphincter using the functional lumen imaging probe: a preliminary report
1School of Clinical Medicine, Trinity College Dublin, Ireland. reganju@tcd.ie
Abstract:
Objective and reliable evaluation of upper esophageal sphincter (UES) opening during swallowing based on videofluoroscopy and pharyngeal manometry challenges dysphagia clinicians. The functional lumen imaging probe (FLIP) is a portable tool based on impedance planimetry originally designed to measure esophogastric junction compliance. It is hypothesized that FLIP can evaluate UES distensibility, and can provide UES diameter and pressure measurements at rest, during swallowing, and during voluntary maneuvers. Eleven healthy adult subjects consented to FLIP evaluation. The probe was inserted transorally, and the balloon was positioned across the UES. Two 20-mL ramp distensions were completed. Changes in UES diameter and intraballoon pressure were measured during dry and 5-mL liquid swallows, and during voluntary swallow postures and maneuvers employed in clinical practice. The protocol was completed by 10 of 11 healthy subjects. Mean intraballoon pressure increased throughout 5-mL (5.8 mmHg; -4.5-18.6 mmHg), 10-mL (8.7 mmHg; 2.3-28.5 mmHg), 15-mL (17.3 mmHg; 9.5-34.8 mmHg), and 20-mL (31.2 mmHg; 16-46.3 mmHg) balloon volumes. Mean resting UES diameter (4.9 mm) increased during dry swallows (9.2 mm) and 5-mL liquid swallows (7.7 mm). Mean UES diameter increased during 5-mL liquid swallows with head turn to right (8.1 mm) and left (8.3 mm), chin tuck (8.4 mm), effortful swallow (8.5 mm), Mendelsohn maneuver (8.1 mm), and supraglottic swallow (7.8 mm). FLIP was safely inserted and distended in the UES, and provided useful quantitative data regarding UES distensibility and UES diameter changes during swallowing maneuvers. Further research is being conducted to explore the role of FLIP in UES evaluation.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...