Related Experiment Video
Updated: Aug 12, 2026

Murine Oropharyngeal Aspiration Model of Ventilator-associated and Hospital-acquired Bacterial Pneumonia
Published on: June 28, 2018
Manual translaryngeal jet ventilation and the risk of aspiration in a canine model
D M Yealy1, M C Plewa, J J Reed
1Division of Emergency Medicine, University of Pittsburgh, Pennsylvania.
Study Objectives:
Manual translaryngeal jet ventilation (TLJV) is a safe and effective method of maintaining normal ventilation in apneic subjects. Little data exist on the amount of airway protection afforded with this technique of airway management. We sought to evaluate the risk of aspiration during manual TLJV.
Setting:
Data were collected in a laboratory animal model.
Design:
A prospective, nonrandomized, controlled trial was performed.
Participants:
Seventeen adult apneic mongrel dogs were enrolled.
Interventions:
Intratracheal Gastrograffin was instilled and radiographic changes assessed during ventilation using a 0 to 3 scale (none to severe). Thirty-six trials were performed, with equal numbers at both 30 degrees and 45 degrees head elevation. The three groups studied were animals without airway protection (control), animals with a cuffed endotracheal tube (tube), and animals with a percutaneous TLJV cannula and a 50-psi oxygen source ventilated at a rate of 20 breaths per minute (jet).
Measurements And Main Results:
Significantly less radiographic evidence of aspiration was noted in the jet and tube groups at 30 degrees and 45 degrees compared with control animals (P = .002 each). At 45 degrees head elevation a trend toward increased aspiration scores in the jet group compared with the tube group (P = .065) was observed.
Conclusion:
In our model, manual TLJV at 20 breaths per minute and an I:E ratio of 1:2 provided protection from aspiration comparable to that observed with a cuffed endotracheal tube at 30 degrees head elevation. At 45 degrees elevation, this protection was diminished.
More Related Videos
04:30Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
07:45Minimally Invasive Murine Laryngoscopy for Close-Up Imaging of Laryngeal Motion During Breathing and Swallowing
Published on: December 1, 2023
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques