Related Experiment Video
Updated: May 24, 2026

Povidone Iodine Rectal Preparation at Time of Prostate Needle Biopsy is a Simple and Reproducible Means to Reduce Risk of Procedural Infection
Published on: September 21, 2015
[Detectors of fluid absorption during transurethral resection of prostate using saline as irrigant solution]
Yuko Watanabe1, Akemi Shido, Yoji Saito
1Department of Anesthesiology, Shimane University, Faculty of Medicine, Izumo 693-8501.
Background:
Although transurethral resection of prostate (TURP) using saline as irrigant solution (TURis) is reported to reduce intraoperative hyponatremia, careful management during operation is needed to avoid complications caused by possible massive absorption of irrigant solution.
Methods:
To find out the detectors of fluid absorption during TURP using TURis system, intraoperative data of hemodynamics and serum electrolytes in 11 patients who had TURP using TURis system were retrospectively collected and statistically analyzed.
Results:
During TURP using TURis system, serum chloride (s-Cl) significantly increased (before/60 min after beginning of operation: 99.4 +/- 2.8/104.2 +/- 5.1 mEq x l(-1), mean +/- SD). Intraoperative changes in s-Cl had strong correlations with changes in base excess, serum potassium, hematocrit and central venous pressure.
Conclusions:
Our results suggested intravenous absorption of saline solution during operation. Serum chloride concentration can be a useful detector of irrigant solution absorption during TURP using TURis system.
Related Concept Videos
Imaging Studies II: Ultrasonography
Urologic Endoscopic Procedure: Cystoscopic Examination
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography