Related Experiment Video
Updated: May 24, 2026

Electromagnetic Source Imaging in Presurgical Evaluation of Children with Drug-Resistant Epilepsy
Published on: September 20, 2024
Subspace electrode selection methodology for the reduction of the effect of uncertain conductivity values in the EEG
G Crevecoeur1, V Montes Restrepo, S Staelens
1Department of Electrical Energy, Systems and Automation, Ghent University, Sint-Pietersnieuwstraat 41, B-9000 Ghent, Belgium. Guillaume.Crevecoeur@ugent.be
Abstract:
The simulation of the electroencephalogram (EEG) using a realistic head model needs the correct conductivity values of several tissues. However, these values are not precisely known and have an influence on the accuracy of the EEG source analysis problem. This paper presents a novel numerical methodology for the increase of accuracy of the EEG dipole source localization problem. The presented subspace electrode selection (SES) methodology is able to limit the effect of uncertain conductivity values on the solution of the EEG inverse problem, yielding improved source localization accuracy. We redefine the traditional cost function associated with the EEG inverse problem and introduce a selection procedure of EEG potentials. In each iteration of the presented EEG cost function minimization procedure, potentials are selected that are affected as little as possible by the uncertain conductivity value. Using simulation data, the proposed SES methodology is able to enhance the neural source localization accuracy dependent on the dipole location, the assumed versus actual conductivity and the possible noise in measurements.