Related Experiment Video
Updated: May 23, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Usefulness of assessing repeater F-waves in routine studies
Elisabeth Chroni1, Isabel Serrano Tendero, Anna Rostedt Punga
1Department of Neurology, School of Medicine, University of Patras, Patras, Rion 26504, Greece. echroni@yahoo.com
Introduction:
Repeater F-waves are sometimes seen in routine studies.
Methods:
We retrospectively reviewed the clinical significance of repeater F-waves in median, ulnar, and fibular nerve recordings in 50 healthy subjects and groups of 50 patients each with diabetic polyneuropathy, amyotrophic lateral sclerosis, carpal tunnel syndrome, ulnar mononeuropathy, and L5 root lesion. The number of identical F-waves and their repetitions in samples of 20 stimuli were estimated.
Results:
Repeater F-waves occurred significantly more frequently in all nerves and patient groups than in healthy individuals. Their persistence was negatively correlated with that of non-repeater F-waves.
Conclusions:
Based on the presented material and recording condition it appears that repeater F-waves differentiate between health and disease but not between different types of pathology of motor neurons or their axons. Even in routinely recorded samples of 20 traces, the index of repeater all F-waves could be used as a sign of nerve pathology.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
08:19Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Special considerations while measuring pulse