Nebulizing conditions of pneumatic electrospray ionization significantly influence electrolyte effects on compound
1Laboratory of DMPK Research of Herbal Medicines, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, China.
Abstract:
Composition of mobile phase can greatly influence the success of electrospray ionization (ESI)-interfaced liquid chromatography-mass spectrometry analysis. To investigate the relationship between formic-acid-based modification of mobile phase and ESI nebulizing conditions, an API 4000 ESI source and a TSQ Quantum one were compared under the same chromatographic conditions. Ginkgo terpene lactones and flavonols were measured in plasma, which involved using ascorbic acid to circumvent cross-interference between the analytes. ESI responses to using formic acid included changes in signal intensity, matrix effect, and upper limit of quantification. Significant disparities in the responses were observed between the two ESI sources, suggesting that the use of electrolyte modifier in liquid chromatography mobile phase and the pneumatic nebulization for ESI should be properly balanced to accomplish optimal ESI-based analysis. The distribution of unpaired ions toward the surface of the initial droplet was assumed to be an important step in the pneumatic ESI process. When using the electrolyte in mobile phase, a too fast droplet reduction by rapid-heating-assisted pneumatic nebulization could negatively decrease the time available for the unpaired ions to migrate from droplet interior to its surface. Ascorbic acid was identified as a major interfering substance for the bioanalytical assay; the interference mechanism might be associated with hindering the unpaired analyte ions from distributing toward the droplet surface rather than outcompeting the analyte ions for the limited excess charge on droplets surface. The current work extends the knowledge base of pneumatic ESI, which has implication for optimal use of the ESI-interfaced liquid chromatography-mass spectrometry technique.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Ionic Strength: Effects on Chemical Equilibria
In this solution, the primary cation—the calcium...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Colloidal precipitates