Jove
Visualize
Contact Us

Related Concept Videos

¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
IR Spectroscopy: Molecular Vibration Overview01:24

IR Spectroscopy: Molecular Vibration Overview

When Infrared (IR) radiation passes through a covalently bonded molecule, the bonds transition from lower to higher vibrational levels. The fundamental vibrational motions that result in infrared absorption can be classified as stretching or bending vibrations.
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR01:15

¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR

The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration01:16

IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration

A covalently bonded heteronuclear diatomic molecule can be modeled as two vibrating masses connected by a spring. The vibrational frequency of the bond can be expressed using an equation derived from Hooke's law, which describes how the force applied to stretch or compress a spring is proportional to the displacement of the spring. In this case, the atoms behave like masses, and the bond acts like a spring.
According to Hooke's law, the vibrational frequency is directly proportional to the...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution00:52

¹H NMR of Conformationally Flexible Molecules: Temporal Resolution

At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Quantitative evaluation of the effects of flow diverter treatment on aneurysm hemodynamics using time-resolved rotational angiography.

Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences·2024
Same author

Endoscopic Endonasal Treatment of a Sinonasal Vascular Neoplasm in the Postnatal Period: Case Report and Review of Literature.

The Annals of otology, rhinology, and laryngology·2021
Same author

Trimodal embolization of juvenile nasopharyngeal angiofibroma with intracranial extension.

International journal of pediatric otorhinolaryngology·2019
Same author

Zn<sup>2+</sup>-binding in the glutamate-rich region of the intrinsically disordered protein prothymosin-alpha.

Journal of biological inorganic chemistry : JBIC : a publication of the Society of Biological Inorganic Chemistry·2018
Same author

Modeling, characterizing, and accommodating static birefringence in circular and linear dichroism spectroscopy.

Applied spectroscopy·2013
Same author

Novel technique for improvement in calibration of the photoelastic modulator in circular and linear dichroism spectroscopy.

Applied spectroscopy·2013
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 23, 2026

CD Spectroscopy to Study DNA-Protein Interactions
06:48

CD Spectroscopy to Study DNA-Protein Interactions

Published on: February 10, 2022

Noise characterization in circular dichroism spectroscopy.

Julie M DiNitto1, John M Kenney

  • 1Department of Physics, East Carolina University, Howell Science Complex, E. 10th Street, Greenville, North Carolina 27858-4353, USA.

Applied Spectroscopy
|March 28, 2012
PubMed
Summary
This summary is machine-generated.

This study presents methods to characterize circular dichroism (CD) spectrometers, optimizing data collection and understanding noise. The findings help ensure accurate structural analysis of chiral materials using CD spectroscopy.

More Related Videos

Protocol for the Solid-phase Synthesis of Oligomers of RNA Containing a 2'-O-thiophenylmethyl Modification and Characterization via Circular Dichroism
11:37

Protocol for the Solid-phase Synthesis of Oligomers of RNA Containing a 2'-O-thiophenylmethyl Modification and Characterization via Circular Dichroism

Published on: July 28, 2017

Performing Spectroscopy on Plasmonic Nanoparticles with Transmission-Based Nomarski-Type Differential Interference Contrast Microscopy
08:54

Performing Spectroscopy on Plasmonic Nanoparticles with Transmission-Based Nomarski-Type Differential Interference Contrast Microscopy

Published on: June 5, 2019

Related Experiment Videos

Last Updated: May 23, 2026

CD Spectroscopy to Study DNA-Protein Interactions
06:48

CD Spectroscopy to Study DNA-Protein Interactions

Published on: February 10, 2022

Protocol for the Solid-phase Synthesis of Oligomers of RNA Containing a 2'-O-thiophenylmethyl Modification and Characterization via Circular Dichroism
11:37

Protocol for the Solid-phase Synthesis of Oligomers of RNA Containing a 2'-O-thiophenylmethyl Modification and Characterization via Circular Dichroism

Published on: July 28, 2017

Performing Spectroscopy on Plasmonic Nanoparticles with Transmission-Based Nomarski-Type Differential Interference Contrast Microscopy
08:54

Performing Spectroscopy on Plasmonic Nanoparticles with Transmission-Based Nomarski-Type Differential Interference Contrast Microscopy

Published on: June 5, 2019

Area of Science:

  • Spectroscopy
  • Analytical Chemistry
  • Physical Chemistry

Background:

  • Circular dichroism (CD) spectroscopy is crucial for analyzing chiral materials.
  • Standardized performance characterization of CD spectrometers is essential for reliable data.
  • Understanding instrument limitations is key to accurate structural elucidation.

Purpose of the Study:

  • To develop and present methodologies for comprehensive CD spectrometer performance characterization.
  • To establish optimal experimental conditions for CD data acquisition.
  • To quantify noise sources and spectral data significance in CD measurements.

Main Methods:

  • Characterization of experimental conditions for optimal CD data collection.
  • Analysis of noise characteristics as a function of machine parameters.
  • Determination of spectral data significance relative to detector gain (High Tension voltage).
  • Quantification of stray light and dark current across wavelengths.

Main Results:

  • CD signal variation follows a Poisson distribution, indicative of shot noise.
  • Optimal scan parameters were established for Jasco J810 and J815 spectrometers.
  • A weighting function was developed to account for wavelength-dependent detector gain.
  • Stray light and dark current were quantified for the photomultiplier tube detector.

Conclusions:

  • The presented methodologies provide a framework for characterizing CD spectrometer performance.
  • The findings enable optimization of experimental parameters for accurate CD spectral data.
  • The developed methods are applicable to various CD spectrometers, regardless of manufacturer, for improved chiral material analysis.