[Assessment of the exposure dose value displayed on operator console in a computed tomography system deciding
Hiroyasu Sanai1, Tatsushi Tomomitsu, Hiroyuki Ikenaga
1Department of Radiological Technology, Kawasaki Medical School Hospital.
Abstract:
The aim of this study was to assess the exposure dose value (DLP) displayed on the operator console in a computed tomography system with automatic exposure control (CT-AEC) which decides the exposure dose from a positioning image. We measured exposure dose with two kinds of CT systems and evaluated the error of the displayed DLP value on the operator console against the measured DLP value. The assessment was performed in three sites: head and neck, upper chest, and lower abdomen. As a result, the errors of displayed value with CT-AEC against the error without CT-AEC in system A (4.09%) were significantly different on two assessment sites (head and neck: -4.02%, upper chest: 6.60%). There is no significant difference on the third assessment site (lower abdomen: 0.06%). On the other hand, those values in system B (8.38%) were almost similar with no significant differences (head and neck: -1.12%, upper chest: -1.85%, lower abdomen: -0.64%). The results show that there were significant differences noted between the errors of displayed value with CT-AEC and without CT-AEC in system A for the head and neck and the upper chest. In conclusion, displayed value with CT-AEC and without CT-AEC were about the same error. However, the possibility that the error depended on a model and the examination site of CT was shown.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
X-ray Imaging
Biological Effects of Radiation