Transatrial transcatheter tricuspid valve-in-valve technique
Anson Cheung1, Jia-Lin Soon, John G Webb
1Division of Cardiac Surgery, St Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada. acheung@providencehealth.bc.ca
Journal of Cardiac Surgery
|March 31, 2012
Abstract:
A novel approach to reoperative tricuspid valve replacement using the transcatheter valve-in-valve concept is studied. Three consecutive transapica transcatheter tricuspid Sapien balloon-expandable valve-in-valve cases, including the first-in-man case, are described. The technical lessons learnt and the clinical outcomes are elaborated.