Dual frequency open-loop electric potential microscopy for local potential measurements in electrolyte solution with

Naritaka Kobayashi1, Hitoshi Asakawa, Takeshi Fukuma

  • 1Frontier Science Organization, Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.

Summary

A new dual frequency mode for open-loop electric potential microscopy (OL-EPM) allows measurements in strong electrolyte solutions. This advancement expands the application of OL-EPM in biology and chemistry.

Related Concept Videos

Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
Potentiometry: Overview01:06

Potentiometry: Overview

Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as the...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current passing...
Junction Potentials in Galvanic Cells01:21

Junction Potentials in Galvanic Cells

The Nernst equation, derived under the assumption of thermodynamic equilibrium, calculates the electromotive force (emf) as the sum of potential differences at phase boundaries in a reversible cell without a liquid junction. However, in irreversible cells such as the Daniell cell, an additional potential difference named the liquid-junction potential (EJ) arises across the interface of two electrolyte solutions due to different ion diffusion rates. This EJ represents the potential difference...
Applications of EMF Measurements01:26

Applications of EMF Measurements

Electromotive force (EMF) measurements have a broad range of applications in various fields, including chemistry and physics. The electrochemical series, an arrangement of elements in order of their standard electrode potentials, can be determined through EMF measurements. Elements with lower standard potentials can reduce ions of elements with higher standard potentials.The standard cell potential, E°, allows for the calculation of the standard reaction Gibbs energy, ΔG°, and the equilibrium...