Related Experiment Video
Updated: May 23, 2026

Implementation of a Real-Time Psychosis Risk Detection and Alerting System Based on Electronic Health Records using CogStack
Published on: May 15, 2020
Predictive combinations of monitor alarms preceding in-hospital code blue events
Xiao Hu1, Monica Sapo, Val Nenov
1Neural Systems and Dynamics Laboratory, Department of Neurosurgery, David Geffen School of Medicine, University of California, Los Angeles, CA, USA. xhu@mednet.ucla.edu
Abstract:
Bedside monitors are ubiquitous in acute care units of modern healthcare enterprises. However, they have been criticized for generating an excessive number of false positive alarms causing alarm fatigue among care givers and potentially compromising patient safety. We hypothesize that combinations of regular monitor alarms denoted as SuperAlarm set may be more indicative of ongoing patient deteriorations and hence predictive of in-hospital code blue events. The present work develops and assesses an alarm mining approach based on finding frequent combinations of single alarms that are also specific to code blue events to compose a SuperAlarm set. We use 4-way analysis of variance (ANOVA) to investigate the influence of four algorithm parameters on the performance of the data mining approach. The results are obtained from millions of monitor alarms from a cohort of 223 adult code blue and 1768 control patients using a multiple 10-fold cross-validation experiment setup. Using the optimal setting of parameters determined in the cross-validation experiment, final SuperAlarm sets are mined from the training data and used on an independent test data set to simulate running a SuperAlarm set against live regular monitor alarms. The ANOVA shows that the content of a SuperAlarm set is influenced by a subset of key algorithm parameters. Simulation of the extracted SuperAlarm set shows that it can predict code blue events one hour ahead with sensitivity between 66.7% and 90.9% while producing false SuperAlarms for control patients that account for between 2.2% and 11.2% of regular monitor alarms depending on user-supplied acceptable false positive rate. We conclude that even though the present work is still preliminary due to the usage of a moderately-sized database to test our hypothesis it represents an effort to develop algorithms to alleviate the alarm fatigue issue in a unique way.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Cardiopulmonary Resuscitation IV: Pharmacological Management
Errors occurring during blood pressure monitoring
Several factors...
