Control charts in healthcare quality improvement. A systematic review on adherence to methodological criteria
A Koetsier1, S N van der Veer, K J Jager
1Antonie Koetsier, MSc, Dept. of Medical Informatics, Academic Medical Center, Room J1b-115-2, P.O. Box 22700, 1100 DE Amsterdam, The Netherlands. a.koetsier@amc.uva.nl
Objectives:
Use of Shewhart control charts in quality improvement (QI) initiatives is increasing. These charts are typically used in one or more phases of the Plan Do Study Act (PDSA) cycle to monitor summaries of process and outcome data, abstracted from clinical information systems, over time. We summarize methodological criteria of Shewhart control charts and investigate adherence of published QI studies to these criteria.
Methods:
We searched Medline, Embase and CINAHL for studies using Shewhart control charts in QI processes in direct patient care. We extracted methodological criteria for Shewhart control charts, and for the use of these charts in PDSA cycles, from textbooks and methodological literature.
Results:
We included 34 studies, presenting 64 control charts of which 40 control charts plotted two phases of the PDSA cycle. The criterion to use 10-35 data points in a control chart was least adhered to (48.4% non-adherence). Other criteria were: transformation of the data in case of a skewed distribution (43.7% non adherence), when comparing data from two phases of the PDSA cycle the Plan phase (the first phase) needs to be stable (40.0% non-adherence), using a maximum of four different rules to detect special cause variation (14.1% non-adherence), and setting control limits at three standard deviations from the mean (all control charts adhered).
Conclusion:
There is room for improvement with regard to the methodological construction of Shewhart control charts used in QI processes. Higher adherence to all methodological criteria will decrease the risk of incorrect conclusions about the process being monitored.
Related Concept Videos
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Methods of Documentation VI: Case Management Model
For example, a patient with a chronic illness...
Introduction to Statistical Process Control
Methods of Documentation IV: Focus Charting
It typically involves three columns for recording information:
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Interpreting Run Charts