Related Experiment Video
Updated: May 22, 2026

Measurement of the Pressure-volume Curve in Mouse Lungs
Published on: January 27, 2015
The validity of static lung compliance in asbestos-induced diseases
Joachim Schneider1, Rolf Arhelger, Wolfgang Raab
1Institut und Poliklinik für Arbeits- und Sozialmedizin der Justus-Liebig-Universität, Aulweg 129/III, 35385 Giessen, Germany. Joachim.Schneider@arbmed.med.uni-giessen.de
Background:
Pulmonary compliance can be viewed as an indicator of distensibility of the lungs, not only in asbestos-induced pulmonary disorders but also in visceral pleural fibrosis extending into the lung parenchyma. In this study we evaluated static compliance measurements in asbestos-derived diseases, especially in patients with parietal pleura plaques. Lung function analyses, especially static lung compliance, were correlated with high-resolution computer tomography examinations.
Methods:
Sixty-three patients with parietal pleural plaques, 10 with visceral pleural fibrosis, 39 with parenchymal pulmonary asbestosis together with parietal pleural plaques, and 42 with parenchymal pulmonary asbestosis together with visceral pleural fibrosis were enrolled in the study.
Results:
In comparison with patients having only parietal pleural plaques, those having asbestosis and visceral pleural fibrosis showed significant decreases in static lung compliance, diffusing capacity, and vital capacity. Visceral pleural thickening was also associated with significantly reduced FEV(1), MEF(50), and FEV(1)/FVC ratios. Multiple regression analyses indicated that the existence of visceral pleural fibrosis (p = 0.017) is the most important factor accounting for a decrease in static compliance. Reference values of static lung compliance differ notably. In comparison with mean reference values, the sensitivity of detecting reduced lung compliance was calculated to be between 9.7 and 45.5 %. Other respiratory function variables failed to show any significant differences.
Conclusion:
Our data indicate that the measurement of static compliance is not sufficient for early detection of pulmonary function impairment in patients with parietal pleural plaques.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease II: Emphysema
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features
Atelectasis II: Pathophysiology
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chronic Obstructive Pulmonary Disease I: Introduction

