Related Experiment Video
Updated: May 22, 2026

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
An accurate maxillary superior repositioning technique without intraoperative measurement in bimaxillary orthognathic
1Department of Oral and Maxillofacial Surgery, Yokohama City University Medical Center, Japan.
Abstract:
This article describes a simple and accurate technique for maxillary superior repositioning without any intraoperative measurement using reference points that can be the source of error in bimaxillary orthognathic surgery. A bilateral straight locking miniplates (SLMs)/screw system secured to the maxilla and mandible maintains the three-dimensional relationship between the mandible and the skull base precisely like the incisor pin of an articulator in model surgery. The maxilla can then be accurately moved into the planned position identical to that in model surgery by the SLMs technique.
More Related Videos
07:32Measuring Maxillary Posterior Tooth Movement: A Model Assessment using Palatal and Dental Superimposition
Published on: February 23, 2024
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021