Sonographic evaluation of bone fractures: a reliable alternative in clinical practice?
Valeria Beltrame1, Roberto Stramare, Nicola Rebellato
1Department of Medical Diagnostic Sciences and Special Therapies, University of Padua, Padova, Italy. valeria.beltrame@unipd.it
Objective:
The objective was to compare the diagnostic accuracy of conventional radiography and ultrasonography (US) for the diagnosis of suspected bone fractures.
Method:
Eighty-six patients were assessed using conventional radiography and US on the affected bone district.
Results:
Radiographic and sonographic findings were concordant in 93% of cases. In one case, US suggested a fracture not seen on radiographic assessment. Ultrasonography showed a sensitivity of 0.94 and a specificity of 0.92.
Conclusion:
In clinical practice, US could become the first diagnostic approach.
More Related Videos
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...