Analysis of chirality by femtosecond laser ionization mass spectrometry

Philipp Horsch1, Gunter Urbasch, Karl-Michael Weitzel

  • 1Philipps-Universität Marburg, Fachbereich Chemie, Marburg, Germany.

Chirality
|May 1, 2012
PubMed

Related Concept Videos

Mass Spectrum: Interpretation01:24

Mass Spectrum: Interpretation

An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Chirality in Nature02:30

Chirality in Nature

Chirality is the most intriguing yet essential facet of nature, governing life’s biochemical processes and precision. It can be observed from a snail shell pattern in a macroscopic world to an amino acid, the minutest building block of life. Most of the snails around the world have right-coiled shells because of the intrinsic chirality in their genes. All the amino acids present in the human body exist in an enantiomerically pure state, except for glycine - the sole achiral amino acid. The...
Chirality02:25

Chirality

Chirality is a term that describes the lack of mirror symmetry in an object. In other words, chiral objects cannot be superposed on their mirror images. For example, our feet are chiral, as the mirror image of the left foot, the right foot, cannot be superposed on the left foot.
Chiral objects exhibit a sense of handedness when they interact with another chiral object. For example, our left foot can only fit in the left shoe and not in the right shoe. Achiral objects — objects that have...
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...