Related Experiment Video
Updated: May 22, 2026

Dynamic Multiparameter Platelet Function Assessment Using a Capacitive Biosensor
Published on: May 2, 2025
Sensitive detection of idiotypic platelet-reactive alloantibodies by an electrical protein chip
Annett Quiel1, Britta Jürgen, Andreas Greinacher
1Pharmazeutische Biotechnologie, Institut für Pharmazie, Ernst-Moritz-Arndt-Universität, Greifswald, Germany.
To prevent and treat immune-mediated platelet disorders (e.g. neonatal allo-immune thrombocytopenia and platelet transfusion refractoriness) the causative idiotypic platelet-reactive antibodies have to be detected with high sensitivity and specificity. The "Monoclonal Antibody Immobilization Platelet Assay" (MAIPA) is the diagnostic gold standard for immunotyping sera with respect to alloantibodies against human platelet antigens (HPA). However, it is labor-intensive and time-consuming. In this work, an automated protein chip assay (enzyme-linked sandwich immunoassay) based on interdigitated gold microelectrodes in combination with an electrical read-out system was developed and optimized. For this purpose, specific capture antibodies were immobilized on the gold electrodes. The binding of the target is detected via an enzyme-labeled detection antibody by a redox-recycling process that corresponds to the amount of bound target molecule. With this electrical chip assay it is possible to detect antibodies against HPA-1a, HPA-5b and HLA with high sensitivity and specificity in less than half the duration of the MAIPA protocol with similar intra- and interassay variance.
To prevent and treat immune-mediated platelet disorders (e.g. neonatal allo-immune thrombocytopenia and platelet transfusion refractoriness) the causative idiotypic platelet-reactive antibodies have to be detected with high sensitivity and specificity. The "Monoclonal Antibody Immobilization Platelet Assay" (MAIPA) is the diagnostic gold standard for immunotyping sera with respect to alloantibodies against human platelet antigens (HPA). However, it is labor-intensive and time-consuming. In this work, an automated protein chip assay (enzyme-linked sandwich immunoassay) based on interdigitated gold microelectrodes in combination with an electrical read-out system was developed and optimized. For this purpose, specific capture antibodies were immobilized on the gold electrodes. The binding of the target is detected via an enzyme-labeled detection antibody by a redox-recycling process that corresponds to the amount of bound target molecule. With this electrical chip assay it is possible to detect antibodies against HPA-1a, HPA-5b and HLA with high sensitivity and specificity in less than half the duration of the MAIPA protocol with similar intra- and interassay variance.
More Related Videos
11:03Use of Capillary Electrophoresis Immunoassay to Search for Potential Biomarkers of Amyotrophic Lateral Sclerosis in Human Platelets
Published on: February 10, 2020
08:58Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood
Published on: April 16, 2016