Related Experiment Video
Updated: May 22, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Performance evaluation of non-targeted peak-based cross-sample analysis for comprehensive two-dimensional gas
Johannes Kiefl1, Chiara Cordero, Luca Nicolotti
1Deutsche Forschungsanstalt für Lebensmittelchemie, Lise-Meitner-Straße 34, 85354 Freising, Germany.
Abstract:
The continuous interest in non-targeted profiling induced the development of tools for automated cross-sample analysis. Such tools were found to be selective or not comprehensive thus delivering a biased view on the qualitative/quantitative peak distribution across 2D sample chromatograms. Therefore, the performance of non-targeted approaches needs to be critically evaluated. This study focused on the development of a validation procedure for non-targeted, peak-based, GC×GC-MS data profiling. The procedure introduced performance parameters such as specificity, precision, accuracy, and uncertainty for a profiling method known as Comprehensive Template Matching. The performance was assessed by applying a three-week validation protocol based on CITAC/EURACHEM guidelines. Optimized ¹D and ²D retention times search windows, MS match factor threshold, detection threshold, and template threshold were evolved from two training sets by a semi-automated learning process. The effectiveness of proposed settings to consistently match 2D peak patterns was established by evaluating the rate of mismatched peaks and was expressed in terms of results accuracy. The study utilized 23 different 2D peak patterns providing the chemical fingerprints of raw and roasted hazelnuts (Corylus avellana L.) from different geographical origins, of diverse varieties and different roasting degrees. The validation results show that non-targeted peak-based profiling can be reliable with error rates lower than 10% independent of the degree of analytical variance. The optimized Comprehensive Template Matching procedure was employed to study hazelnut roasting profiles and in particular to find marker compounds strongly dependent on the thermal treatment, and to establish the correlation of potential marker compounds to geographical origin and variety/cultivar and finally to reveal the characteristic release of aroma active compounds.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...