Background:
Anterior screw fixation has been widely adopted for the treatment of type II dens fractures. However, there is still controversy regarding whether one- or two-screw fixation is more appropriate.
Questions/Purposes:
We addressed three questions: (1) Do one- and two-screw fixation techniques differ regarding shear stiffness and rotational stiffness? (2) Can shear stiffness and rotational stiffness after screw fixation be restored to normal? (3) Does stiffness after screw fixation correlate with bone mineral density (BMD)?
Methods:
We randomly assigned 14 fresh axes into two groups (seven axes each): one receiving one-screw fixation and another receiving two-screw fixation. Shear and torsional stiffness were measured using a nondestructive low-load test in six directions. A transverse osteotomy then was created at the base of the dens and fixed using one or two screws. Shear and torsional stiffness were tested again under the same testing conditions.
Results:
Mean stiffness in all directions after screw fixation was similar in both groups. The stiffness after one- and two-screw fixation was not restored to normal: the mean shear stiffness restored ratio was less than 50% and the mean torsional stiffness restored ratio was less than 6% in both groups. BMD did not correlate with mean stiffness after screw fixation in both groups.
Conclusions:
One- and two-screw fixation for type II dens fractures provide similar stability but neither restores normal shear or torsional stiffness.
Clinical Relevance:
One-screw fixation might be used as an alternative to two-screw fixation. Assumed BMD should not influence surgical decision making.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Structural Joints: Fibrous Joints
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.