In vitro performance testing of a pediatric oxygenator with an integrated pulsatile pump
Ralf Borchardt1, Peter Schlanstein, Ilona Mager
1Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Germany. borchardt@hia.rwth-aachen.de
Abstract:
For different lung and heart diseases (e.g., acute respiratory distress syndrome, congenital heart failure, and cardiomyopathy) extracorporeal membrane oxygenation is a well-established therapy, particularly in the field of neonatal and pediatric medicine. To reduce the priming volume of the extracorporeal circuit, different components can be combined. In this study, an oval-shaped oxygenator (called ExMeTrA) with integrated pulsatile pump was tested in vitro using porcine blood. A feasibility study regarding the performance of collapsing and expanding silicone tubes within an oxygenator fiber bundle as a pulsatile pump was previously completed with successful results. The findings of this study improve upon the previous feasibility results, particularly in terms of gas exchange and filling volume. Five modules were manufactured in sizes of 20 ± 2.2 ml (priming volume) with fiber surface areas of 0.24 ± 0.027 m(2) and an analytically calculated volume pumping capacity of 692 ± 75 ml/min. The modules were made of polymethylpentene fibers with dense outer layer to permit long-term applications. The gas exchange rates at a gas/blood flow ratio of 2:1 were between 64 and 72.7 ml(O)(2)/l(blood) and between 62.5 and 81.5 ml/l(blood), depending on the blood flow. The individual module's pumping capacity ranged from 200-500 ml/min thus providing room for further improvements. In order to enhance the pumping capacity while maintaining sufficient gas exchange rates future optimization, adjustments will be made to the inlet and outlet geometries.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...