Sidestream microstream end tidal carbon dioxide measurements and blood gas correlations in neonatal intensive care
Bindya S Singh1, Urquidez Gilbert, Sharad Singh
1Division of Neonatology, Department of Pediatrics, Santa Clara Valley Medical Center, San Jose, CA, USA. bindya.singh@hhs.sccgov.org
Objective:
The study was designed to assess the use of newer sidestream microstream end tidal carbon dioxide (ETCO(2) ) device in predicting blood carbon dioxide (PCO(2) ) measurements in very low birth weight (VLBW = birth weight <1,500 g) and non-VLBW NICU neonates.
Study Design:
Sidestream microstream ETCO(2) detectors were allowed time to calibrate and reach steady state prior to blood gas measurements. Blood CO(2) (PCO(2) ) and simultaneous ETCO(2) were recorded. Ratio of dead space to tidal volume (VD/VT) was calculated using modified Bohr's equation. Correlation coefficient, estimates of difference, standard deviation, and 95% limits of agreement between ETCO(2) and PCO(2) concentrations were calculated.
Results:
Two hundred eighty-six paired samples were collected from 48 ventilated NICU patients. Average PCO(2) and ETCO(2) were 58.4 and 50.6 with a correlation of 0.76. Subgroup analysis showed a correlation of 0.73 in 204 paired blood from 34 VLBW infants and 0.82 in 82 paired samples from non-VLBW infants. Estimates of difference ± standard deviation between PCO(2) and ETCO(2) concentrations in these three groups, respectively (ALL, VLBW, and non-VLBW) were 7.84 ± 9.96, 8.2 ± 10.16, and 6.95 ± 9.45. The correlation coefficient significantly improved in the VLBW group to 0.86 with dead space to tidal volume ratio (VD/VT) <30% (0.86 vs. 0.42; P < 0.001).
Conclusion:
ETCO(2) measurements using sidestream microstream technology in VLBW demonstrated that the correlation of ETCO(2) and PCO(2) was moderate, but the agreement was less than adequate (bias > 5 mmHg in all groups). The results improved with lower VD/VT, suggesting that sidestream capnography is more reliable in conditions of less severe lung disease.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Regulation of Acid-Base Balance
When carbon dioxide levels increase in the blood, more H+ and HCO3⁻ are produced, leading to a...