Related Experiment Video
Updated: May 22, 2026

Deep Vein Thrombosis Induced by Stasis in Mice Monitored by High Frequency Ultrasonography
Published on: April 13, 2018
The ultrasound frequency determines the degree of intrinsic coagulation activation
Thomas W Stief1, Volker Klingmüller
1Institute of Laboratory Medicine and Pathobiochemistry, University Hospital Giessen & Marburg, Marburg, Germany. thstief@med.uni-marburg.de
Abstract:
Diagnostic ultrasound activates intrinsic coagulation. The aim of the present work was to quantify the action of different ultrasound frequencies on the contact phase of human blood coagulation. Pooled normal citrated platelet-poor plasma in 2 ml aliquots in polypropylene monovettes was exposed to diagnostic ultrasound, changing the ultrasound frequency from 17 to 15 to 12 to 8 to 7 MHz (at an intensity of 1.1 MI). After 0-2 min (23°C), 400 μl samples were withdrawn and placed into polypropylene Eppendorf cups. Forty microliters of plasma sample was pipetted into U-wells polystyrene microtiter plates of high purity (Brand781600). Immediately thereafter, the recalcified coagulation activity assay (RECA) was performed. Seventeen megahertz ultrasound exposure was the weakest activator of intrinsic coagulation of all frequencies tested: even 2 min of exposure at 23°C enhanced F2a generation by only about three-fold. The shorter the ultrasound exposure, the better the action against intrinsic hemostasis: 0.5 min of ultrasound exposure at 23°C induced less than two-fold thrombin generation in all frequencies tested. One minute ultrasound exposure (23°C) triggered intrinsic coagulation strongest at 8 MHz, showing an approximately four-fold increase in F2a generation. A 1.5 min of ultrasound exposure (23°C) triggered coagulation strongest at 7 MHz, showing an approximately 14-fold increase in F2a generation. Two minute of ultrasound exposure (23°C) triggered coagulation strongest at 15 MHz, showing an approximately 18-fold increase in F2a generation. Ultrasound has to be considered as a potential inducer of pathologic systemic coagulation. Patients at risk for increased coagulation activation and/or liver insufficiency should be protected with low molecular weight heparin, if a prolonged ultrasound diagnostic is planned. Ultrasound frequencies of about 17 MHz are the weakest activators of intrinsic coagulation. Ultrasound frequencies of about 7 MHz might be used for therapeutic induction of coagulation activation, such as in patients with severe cerebral or hepatic hemorrhages.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which forms a...
Imaging Studies II: Ultrasonography
Coagulation
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):