Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Control strategies for afterload reduction with an artificial vasculature device
Guruprasad A Giridharan1, Rolando Chip Cheng, Jacob S Glower
1Department of Bioengineering, University of Louisville, Kentucky 40202, USA.
Abstract:
Ventricular assist devices (VADs) have been used successfully as a bridge to transplant in heart failure patients by unloading ventricular volume and restoring the circulation. An artificial vasculature device (AVD) is being developed that may better facilitate myocardial recovery than VAD by controlling the afterload experienced by the native heart and controlling the pulsatile energy entering into the arterial system from the device, potentially reconditioning the arterial system properties. The AVD is a valveless, 80 ml blood chamber with a servo-controlled pusher plate connected to the ascending aorta by a vascular graft. Control algorithms for the AVD were developed to maintain any user-defined systemic input impedance (IM) including resistance, elastance, and inertial components. Computer simulation and mock circulation models of the cardiovascular system were used to test the efficacy of two control strategies for the AVD: 1) average impedance position control (AIPC)-to maintain an average value of resistance during left ventricular (LV) systole and 2) instantaneous impedance force feedback (IIFF) and position control (IIPC)-to maintain a desired value or profile of resistance and compliance. Computer simulations and mock loop tests were performed to predict resulting cardiovascular pressures, volumes, flows, and the resistance and compliance experienced by the native LV during ejection for simulated normal, failing, and recovering LV. These results indicate that the LV volume and pressure decreased, and the LV stroke volume increased with decreasing IM, resulting in an increased ejection fraction. Although the AIPC algorithm is more stable and can tolerate higher levels of sensor errors and noise, the IIFF and IIPC control algorithms are better suited to maintain any instantaneous IM or an IM profile. The developed AVD impedance control algorithms may be implemented with current VADs to promote myocardial recovery and facilitate weaning.
Related Concept Videos
Aortic Regurgitation III: Medical Management
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
Heart Failure V: Medical Management
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Heart Failure VI: Adjunct Therapies