Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 21, 2026

Using Computer-based Image Analysis to Improve Quantification of Lung Metastasis in the 4T1 Breast Cancer Model
08:32

Using Computer-based Image Analysis to Improve Quantification of Lung Metastasis in the 4T1 Breast Cancer Model

Published on: October 2, 2020

New image processing technique for evaluating breast microcalcifications: a comparative study.

Priscilla Machado1, John R Eisenbrey, Barbara Cavanaugh

  • 1Department of Radiology, Thomas Jefferson University, 132 S 10th St, Philadelphia, PA 19107, USA.

Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine
|May 31, 2012
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Umbilical vein recanalization identified on contrast-enhanced ultrasound in a patient with hepatocellular carcinoma during TACE assessment.

Radiology case reports·2026
Same author

Comparison of simulated transient elastography sample volumes and global measurements on MRE and MRI-PDFF in patients with suspected MASLD.

Clinical imaging·2026
Same author

Effects of Pressure Cycling, Concentration, and Excitation Amplitude on Ambient Pressure Sensitivity of Perfluorobutane Microbubbles.

Ultrasound in medicine & biology·2026
Same author

Assessment of Early Breast Cancer Response to Chemotherapy with Ultrasound Radiomics.

Diagnostics (Basel, Switzerland)·2026
Same author

Faster motion correction of clinical contrast-enhanced ultrasound imaging using deep learning.

IEEE International Ultrasonics Symposium : [proceedings]. IEEE International Ultrasonics Symposium·2026
Same author

Performance of CEUS LI-RADS v2017 major feature combinations: individual patient data meta-analysis.

Abdominal radiology (New York)·2026
Same journal

Nurse-Led Ultrasound Competency in Psychiatric Hospitals: A Practical Extension of ULTRA-Metrics.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
Same journal

A Multidisciplinary Call for Standardization in Lung Ultrasound.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
Same journal

From Mechanistic Insights to Clinical Translation: Advances in the Application of Low-Intensity Pulsed Ultrasound for Osteoarthritis Treatment.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
Same journal

Translating AI-Based Biopsy Sparing into Clinically Actionable Decision-Making for BI-RADS 4A+ Breast Lesions.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
Same journal

Comparative Study of Microvascular Flow and Viscoelasticity Imaging in Monitoring Renal Allograft Function.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
Same journal

Deep Learning for Automated Infant Hip Ultrasound: Toward Robust Generalization across Disease Spectrum and Devices.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
See all related articles

MicroPure imaging detected more breast microcalcifications than traditional gray scale ultrasound. This new technique improved reader agreement and reduced artifacts, enhancing diagnostic accuracy for breast calcifications.

Area of Science:

  • Medical imaging
  • Radiology
  • Breast imaging

Background:

  • Mammography is the standard for detecting breast microcalcifications.
  • Gray scale ultrasound (US) is used, but its efficacy for microcalcifications is limited.
  • New image processing techniques aim to improve diagnostic accuracy.

Purpose of the Study:

  • To evaluate MicroPure, a new commercial image processing technique, for identifying breast microcalcifications.
  • To compare MicroPure's performance against gray scale ultrasound (US).
  • To use mammography as the reference standard for comparison.

Main Methods:

  • Twenty women with mammographically confirmed breast calcifications participated.
  • Both gray scale US and MicroPure examinations were performed.

More Related Videos

Clinical Imaging of Microwave Mammography
05:28

Clinical Imaging of Microwave Mammography

Published on: November 14, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

Related Experiment Videos

Last Updated: May 21, 2026

Using Computer-based Image Analysis to Improve Quantification of Lung Metastasis in the 4T1 Breast Cancer Model
08:32

Using Computer-based Image Analysis to Improve Quantification of Lung Metastasis in the 4T1 Breast Cancer Model

Published on: October 2, 2020

Clinical Imaging of Microwave Mammography
05:28

Clinical Imaging of Microwave Mammography

Published on: November 14, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

  • Images were analyzed by blinded radiologists and physicists for calcification detection, image quality, and artifacts.
  • Main Results:

    • MicroPure identified significantly more calcifications than gray scale US at higher sensitivity levels.
    • Reader agreement and agreement with mammography improved substantially with MicroPure.
    • MicroPure demonstrated reduced artifacts and comparable image quality preferences between readers.

    Conclusions:

    • MicroPure imaging significantly enhances the detection of breast microcalcifications compared to gray scale US.
    • The technique offers improved diagnostic performance and reader confidence.
    • MicroPure represents a promising advancement in breast imaging for microcalcification detection.