Thrombus imaging in acute ischaemic stroke using thin-slice unenhanced CT: comparison of conventional sequential CT
1Department of Radiology and the Research Institute of Radiological Science, Yonsei University College of Medicine, 250 Yonsei-ro, Seodaemun-gu, Seoul, 120-752, Republic of Korea.
Objectives:
Thin-slice helical unenhanced CT can be used for thrombus imaging but increases radiation exposure. Conventional sequential images obtained by multidetector CT can be reconstructed into thin-slice images. The purpose of this study was to evaluate if conventional sequential unenhanced CT images can replace helical unenhanced CT for thrombus imaging.
Methods:
Fifty consecutive patients with acute ischaemic stroke underwent both 5-mm conventional sequential unenhanced CT and helical unenhanced CT. Each of the sequential and helical unenhanced CT images was subsequently reconstructed into four 1.25-mm images. Thrombus volumes and HU were measured semi-automatically using both types of unenhanced CT. Thrombus HU ratio (rHU) was calculated using the HU of the contralateral segment. The intraclass correlation coefficient (ICC) and Bland-Altman plots were used to assess measurement agreement.
Results:
The mean rHUs were 1.47 ± 0.17 for sequential unenhanced CT and 1.47 ± 0.18 helical unenhanced CT (P = 0.542). The mean thrombus volumes were 124.25 ± 125.65 mm(3) and 117.84 ± 124.32 mm(3) on sequential and helical unenhanced CT images, respectively (P = 0.063). Measurement agreement between thrombus volumes from the two unenhanced CT images was high (ICC = 0.981).
Conclusions:
Thin-slice unenhanced CT images reconstructed from 5-mm sequential images can replace helical unenhanced CT for thrombus imaging in acute ischaemic stroke.
Key Points:
• Unenhanced CT is used to evaluate intra-arterial thrombus. • Thrombus HU and volume measurements using sequential or helical CT are comparable. • Conventional sequential images can replace helical CT for thrombus imaging. • Radiation dose for thrombus imaging can be reduced using sequential CT.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT