Related Experiment Video
Updated: May 21, 2026

Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF
Published on: October 17, 2025
Complex pediatric cervical spine surgery using smaller nonspinal screws and plates and intraoperative computed
Mahesh Karandikar1, Sohail K Mirza, Kit Song
1Department of Neurological Surgery, Harborview Medical Center, University of Washington School of Medicine, Seattle Children’s Hospital, Seattle, WA, USA. mahesh7069@gmail.com
Insights
Pediatric craniocervical instability surgery is challenging. Using smaller titanium screws and intraoperative CT improved fusion success rates and reduced complications in children.
Area of Science:
- Neurosurgery
- Pediatric Orthopedics
- Spine Surgery
Background:
- Craniocervical instability in children presents unique surgical challenges due to anatomical differences.
- Traditional surgical approaches may be limited by the small size of pediatric vertebral structures.
Observation:
- A study evaluated 33 craniocervical fusion procedures in 31 children (≤17 years) using smaller, nontraditional titanium screws and plates.
- Intraoperative computed tomography (CT) was utilized in 23 procedures to guide hardware placement and assess spinal alignment.
Findings:
- Successful fusion was achieved in all patients by the 3-month follow-up, with one requiring revision surgery.
- Intraoperative CT facilitated the repositioning of 11 suboptimally placed screws, avoiding additional surgeries and improving outcomes.
Implications:
- The use of smaller, nontraditional implants and intraoperative CT enables successful craniocervical fusion in pediatric patients.
- This approach potentially reduces treatment costs and minimizes surgical complications in the pediatric population.
Object:
The treatment of craniocervical instability in children is often challenging due to their small spine bones, complex anatomy, and unique syndromes. The authors discuss their surgical experience with 33 cases in the treatment of 31 children (≤ 17 years of age) with craniocervical spine instability using smaller nontraditional titanium screws and plates, as well as intraoperative CT.
Methods:
All craniocervical fusion procedures were performed using intraoperative fluoroscopic imaging and electrophysiological monitoring. Nontraditional spine hardware included smaller screw sizes (2.4 and 2.7 mm) from the orthopedic hand/foot set and mandibular plates. Twenty-three of the 33 surgical procedures were performed with intraoperative CT, which was used to confirm adequate position of the spine hardware and alignment of the spine.
Results:
The mean patient age was 9.5 years (range 2-17 years). Eleven children underwent a posterior C1-2 transarticular screw fusion, 17 had an occipitocervical fusion, and 3 had a posterior subaxial cervical fusion. The follow-up duration ranged from 9 to 72 months (mean 53 months). All children demonstrated successful fusion at their 3-month follow-up visit, except 1 patient whose unilateral C1-2 transarticular screw fusion required a repeat surgery before proper fusion was achieved. Of the 47 C1-2 transarticular screws that were placed, 13 were 2.4 mm, 15 were 2.7 mm, 7 were 3.5 mm, and 12 were 4.0 mm. Eighteen of the 47 C1-2 transarticular screws were suboptimally placed. Eleven of these misplaced screws were removed and redirected within the same operation because these surgeries benefitted from the use of intraoperative CT; 6 of the 7 remaining suboptimally placed screws were left in place because a second surgery for screw replacement was not warranted. The other suboptimally placed C1-2 screw was replaced during a repeat operation due to failure of fusion. Use of intraoperative CT was invaluable because it enabled the authors to reposition suboptimal C1-2 transarticular screws without necessitating a second operation.
Conclusions:
Successful craniocervical fusion procedures were achieved using smaller nontraditional titanium screws and plates. Intraoperative CT was a helpful adjunct for confirming and readjusting the trajectory of the screws prior to leaving the operating room, which decreases overall treatment costs and reduces complications.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024