Related Experiment Video
Updated: May 21, 2026

Transcutaneous Microcirculatory Imaging in Preterm Neonates
Published on: December 31, 2015
Thermographical measuring of the skin temperature using laser needle acupuncture in preterm neonates
Wolfgang Raith1, Gerhard Litscher, Iris Sapetschnig
1Division of Neonatology, Department of Paediatrics, Medical University of Graz, Auenbruggerplatz 30, 8036 Graz, Austria.
Abstract:
In children, laser acupuncture is used more often than needle acupuncture in Western countries, due to their aversion to needles. When applying laser acupuncture to premature babies and neonates, firstly the degree of the thermal increase to the skin has to be evaluated so as to guarantee safe application. The patients were premature neonates before their discharge from hospital. The measurements were carried out by means of a polygraphy while they were asleep shortly. The large intestine 4 acupoint (LI4, Hegu) was stimulated by a microlaser needle (10 mW, 685 nm) twice (5 and 10 min). Local thermographic pictures were taken with a thermal camera (Flir i5, Flir Systems Inc., Portland, USA), and the warmest point was determined and subsequently compared. The study included 10 premature neonates (7 male, 3 female). The measurements were carried out on the 33rd day of life (weight 2030 g, gestational age 36 + 3 weeks of pregnancy). In comparison to the initial temperature (32.9°C), after 5 minutes of stimulation (33.9°C) (P = 0.025) and also after 10 minutes of stimulation (34.0°C) (P = 0.01), there was found to be a significant increase in the skin temperature. The singular maximum value of 37.9°C bears a potential danger; however, compared to the local temperatures reached in transcutaneous blood gas measurements it appears not to entail any risks.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...