The NMR phased array.

P B Roemer1, W A Edelstein, C E Hayes

  • 1GE Corporate Research and Development Center, Schenectady, New York 12301.

Magnetic Resonance in Medicine
|November 1, 1990
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Pronounced reduction of acquisition of conditioned eyeblink responses in young adults with focal cerebellar lesions impedes conclusions on the role of the cerebellum in extinction and savings.

Neuropsychologia·2016
Same author

Molecular and antigenic characterization of bovine Coronavirus circulating in Argentinean cattle during 1994-2010.

Veterinary microbiology·2015
Same author

Genetic diversity and population structure of Synthesium pontoporiae (Digenea, Brachycladiidae) linked to its definitive host stocks, the endangered Franciscana dolphin, Pontoporia blainvillei (Pontoporiidae) off the coast of Brazil and Argentina.

Journal of helminthology·2015
Same author

MRI Dynamic Range: Theory and Measurement.

Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition·2014
Same author

Accurate Measurement of RF Power Deposition During 3T MRI.

Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition·2014
Same author

A Multi-Channel, High Dynamic Range, Real Time RF Power Deposition Monitor.

Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition·2014
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
Same journal

Evaluation of Phantom Doping Materials in Quantitative Susceptibility Mapping.

Magnetic resonance in medicine·2026
Same journal

Design of an 8-Channel Transmit 32-Channel Receive 11.7T Head Coil and Evaluation of SNR Gains.

Magnetic resonance in medicine·2026
Same journal

The Potential for Absolute Temperature Imaging Based on Brain Metabolites Using an FID-Shifting Approach in Gradient Echo Planar Spectroscopic Imaging (GREPSI).

Magnetic resonance in medicine·2026
See all related articles

We introduce the NMR phased array, a novel technique using multiple NMR coils for enhanced imaging. This method significantly improves signal-to-noise ratio and resolution without increasing scan time.

Area of Science:

  • Magnetic Resonance Imaging
  • Medical Physics
  • Biomedical Engineering

Background:

  • Simultaneous acquisition and combination of data from multiple NMR coils are challenging.
  • Existing methods struggle with signal-to-noise ratio (SNR) and resolution over large fields-of-view (FOV).
  • Interactions between closely positioned coils degrade image quality.

Purpose of the Study:

  • To present a novel technique called the "NMR phased array" for simultaneous data acquisition and combination from multiple NMR coils.
  • To achieve the SNR and resolution of small surface coils over large FOVs without increasing imaging time.
  • To eliminate problematic interactions among nearby coils.

Main Methods:

  • The NMR phased array utilizes overlapping adjacent coils to achieve zero mutual inductance, thus eliminating interaction.

Related Experiment Videos

  • Low input impedance preamplifiers are attached to all coils to prevent interference.
  • An algorithm is derived for optimally combining data from phased array elements to maximize SNR.
  • Phased array imaging is demonstrated using spin-echo sequences on thoracic and lumbar spine phantoms.
  • Main Results:

    • The NMR phased array achieves the SNR and resolution of small surface coils over FOVs typically associated with body imaging.
    • Problematic interactions among coils are eliminated through coil overlap and preamplifier design.
    • Phased array imaging demonstrated high-resolution (512x512) spin-echo images of the spine.
    • Compared to a single coil, the NMR phased array yielded a 2X to 3X higher SNR at a depth of approximately 7 cm.

    Conclusions:

    • The NMR phased array technique significantly enhances SNR and resolution in Magnetic Resonance Imaging (MRI).
    • This method offers a substantial improvement for clinical applications requiring high-quality imaging over large FOVs.
    • The NMR phased array is applicable to both MRI and spectroscopy across all pulse sequences.