Related Experiment Video
Updated: May 21, 2026

Extending the Lifespan of Soluble Lead Flow Batteries with a Sodium Acetate Additive
Published on: January 7, 2019
Effect of flow rate and lead/copper pipe sequence on lead release from service lines
Clément Cartier1, Roger B Arnold, Simoni Triantafyllidou
1NSERC Industrial Chair in Drinking Water, École Polytechnique de Montréal, Civil, Geological and Mining Engineering, PO Box 6079, Station Centre-ville, Montreal, Quebec, Canada H3C 3A7. clement.cartier@polymtl.ca
Abstract:
A pilot experiment examined lead leaching from four representative configurations of service lines including: (1) 100% lead (Pb), (2) 100% copper (Cu), (3) 50% Pb upstream of 50% Cu, and (4) 50% Pb-downstream of 50% Cu using a range of flow rates. The cumulative mass of lead release indicated that a typical partial replacement configuration (50% lead downstream of copper) did not provide a net reduction in lead when compared to 100% lead pipe (85 mg for 50% Pb-downstream versus 83 mg for 100%-Pb) due to galvanic and deposition corrosion. The partially replaced service line configuration also had a much greater likelihood of producing water with "spikes" of lead particulates at higher flow rates, while tending to produce lower levels of lead at very low flow rates. After the first 214 days the galvanic current between copper and lead was only reduced by 34%, proving that galvanic impacts can be highly persistent even in water with optimized corrosion control by dosing of zinc orthophosphate. Finally, this experiment raises concern about the low flow rates used during some prior home sampling events, which may underestimate exposure to lead during normal water use, especially when galvanic Pb:Cu connections are present.
More Related Videos
08:25Measurements of Local Instantaneous Convective Heat Transfer in a Pipe - Single and Two-phase Flow
Published on: April 30, 2018
16:21Quantifying Fish Swimming Behavior in Response to Acute Exposure of Aqueous Copper Using Computer Assisted Video and Digital Image Analysis
Published on: February 26, 2016
Related Concept Videos
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are known. The...
Design Example: Designing a Residential Plumbing System
General Characteristics of Pipe Flow I
The classification of fluid...
Design Example: Flow of Oil Through Circular Pipes
General Characteristics of Pipe Flow II
The distance to reach a fully developed flow is called the entrance length and depends on the flow...
Pipe Flowrate Measurement: Problem Solving