Objective:
To investigate whether the aerobic capacity of older adults who underwent a lower limb amputation is associated with the presence, cause (traumatic or vascular), and level of amputation (transtibial or transfemoral).
Design:
Cross-sectional descriptive.
Setting:
Human motion laboratory at a rehabilitation center.
Participants:
Older subjects (n=36) who underwent lower limb amputation and age-matched, able-bodied controls (n=21). All subjects were able to walk for a minimum of 4 minutes.
Interventions:
Not applicable.
Main Outcome Measure:
Peak oxygen consumption (Vo(2)(peak)) was measured using open-circuit respirometry while performing a discontinuous, graded, 1-legged, peak cycle exercise test.
Results:
After correcting for age, body mass index, and sex, the multiple linear regression analysis revealed that subjects who underwent amputation had a 13.1% lower aerobic capacity compared with able-bodied controls (P=.021). Differentiation among etiologies revealed that subjects with a vascular amputation had a lower Vo(2)(peak) of 29.1% compared with able-bodied controls (P<.001), whereas traumatic amputees did not differ from able-bodied controls (P=.127). After correcting for etiology, no association between level of amputation and Vo(2)(peak) was found (P=.534).
Conclusions:
Older adults who underwent an amputation because of vascular deficiency had a lower aerobic capacity compared with able-bodied controls and people with a traumatic amputation. The level of amputation was not associated with Vo(2)(peak).
Related Concept Videos
Oxygen Transport in the Blood
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Factors Affecting Respiration
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...