Related Experiment Video
Updated: May 21, 2026

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Effect of respirator resistance on tolerant capacity during graded load exercise
1School of Public Health, PeKing University, Beijing, 100191, China.
Abstract:
Respirator breathing resistance impacts performance of wearers during constant work load. However, it is less clear as to how breathing resistance affects the tolerant capacity of users during graded work load. The present study investigated the tolerant capacity of 8 individuals during incremental work load. The 8 subjects were required to wear two matched respirators (respirators I and II which were designed to have different breathing resistances and the same dead space) respectively on separate days and then work to end points. Minute ventilation (V(E)), breathing frequency (BF), oxygen consumption (VO(2)) and heart rate (HR) were recorded during exercise, while tolerant time, response time and breathing discomfort were measured at the end of each test trial. The test variables were compared between the two respirators by using matched-pairs t-test. The results showed that the tolerant time was significantly reduced for the respirator I with higher level of breathing resistance when compared with its counterpart with lower breathing resistance (respirator II) (P<0.05). The same changes occurred for response time. Results also showed a significant increase in V(E) and BF for respirator I wearers when the work load was above 125 W. The O(2) consumption was similar under the two breathing resistance conditions. These findings suggested that the respiratory resistance caused by self-contained breathing apparatus (SCBA) has an impact on the tolerant capacity of users.
More Related Videos
Related Concept Videos
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...

