Related Experiment Video
Updated: May 21, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Low preoperative cerebral oxygen saturation is associated with longer time to extubation during fast-track cardiac
Hauke Paarmann1, Thorsten Hanke, Matthias Heringlake
1Department of Anesthesiology, University of Lübeck, Lübeck, Germany.
Objectives:
Fast-track cardiac anaesthesia programs aiming at early tracheal extubation have not only been linked to a decrease in intensive care unit and hospital length of stay but also to a decrease in morbidity and mortality as well as a containment of rising medical costs. General recommendations for the inclusion criteria concerning fast-track programs are not available.
Methods:
The present study determined the factors influencing the time to extubation in patients undergoing a newly implemented fast-track protocol. Seventy-nine patients were retrospectively studied. Successful fast track was defined as time to extubation within 75 min after admission to ICU.
Results:
Sixty patients fulfilled the successful fast-track criteria with a mean time to extubation of 43.9 min (range 15-75 min). Nineteen patients needed more than 75 min to be weaned from the respirator with a mean time to extubation of 135 min (range 90-320 min). Analysis of pre- and intraoperative factors revealed that these groups differed only with respect to preoperative cerebral oxygen saturation levels: 67.7 ± 5.2 versus 60.8 ± 7.4%.
Conclusions:
Cerebral oxygen saturation assessment prior to cardiac surgery is significantly related to time to extubation and may thus be used to stratify candidates in fast-track programs.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiopulmonary Resuscitation II: ACLS Airway Management
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
