Chromatographic models to predict the elution of ionizable analytes by organic modifier gradient in reversed phase
Axel Andrés1, Adolfo Téllez, Martí Rosés
1Departament de Química Analítica and Institut de Biomedicina-IBUB, Universitat de Barcelona, C/Martí i Franquès 1-11, 08028 Barcelona, Spain.
Abstract:
The retention of an ionizable analyte under RP-HPLC organic modifier gradient elution is strongly affected by its ionization degree which, in turn, depends on its pK(a) and on the pH of the mobile phase. The values of both parameters change depending on the mobile phase composition and thus retention becomes a parameter quite difficult to predict, particularly when working in gradient mode. In this work, an equation describing the retention of ionizable analytes has been combined with three different models of different complexity, developed for gradient elution of neutral compounds (1, 2, or 3 fitting parameters), in order to predict retention of compounds with acid-base properties with particular buffers. All models have been tested under 16 different gradient patterns (4 linear gradients, 4 concave gradients, 4 convex gradients and 4 combinations between them) for the prediction of the retention time of 12 acid-base compounds (pK(a) values from 4 to 9) in 3 different buffered mobile phases (pH 5, pH 7 and pH 9) with acetonitrile as organic modifier. The agreement between the experimental and calculated retention times is good for all models. The best results are obtained through the model that depends on three parameters and the accuracy of the two-parameter model is slightly lower but very acceptable too. On the other hand, the predictions performed with the one-parameter model are the less accurate, but good enough to become a valid model taking into account that it requires very little experimental work.
More Related Videos
10:41Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
11:25Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Chromatographic Methods: Terminology