Related Experiment Video
Updated: May 21, 2026

RNAscope for In situ Detection of Transcriptionally Active Human Papillomavirus in Head and Neck Squamous Cell Carcinoma
Published on: March 11, 2014
Near-infrared Raman Microspectroscopy Detects High-risk Human Papillomaviruses
Elizabeth Vargis1, Yi-Wei Tang, Dineo Khabele
1Department of Biomedical Engineering, Vanderbilt University, Nashville, TN.
Background:
Detecting human papillomaviruses (HPVs) infection in cervical cells is an exceedingly important part of the clinical management of cervical dysplasia. Current guidelines in women's health outline the need for both the Papanicolaou test as well as high-risk HPV testing. Testing for HPV is expensive, is time-consuming, and requires experienced technicians.
Methods:
Two sets of near-infrared Raman microspectroscopy experiments were conducted using a Raman confocal microscope system. First, Raman spectra were acquired from four different cell culture lines, two positive for HPV (HeLa, SiHa), one negative for HPV, but malignant (C33A), and one normal, HPV-negative line (NHEK). The three malignant lines were all derived from cervical cells. Second, Raman spectra were acquired from deidentified patient samples that were previously tested for the presence of high-risk HPV.
Results:
The spectra from the cell culture lines and the patient samples contained many statistically significant differences. Using sparse multinomial logistic regression to classify the data led to classification accuracies of 89% to 97% for the cell culture samples and 98.5% for the patient samples.
Conclusions:
Raman micro-spectroscopy can be used to detect HPV and differentiate among specific HPV strains. This technique may provide health providers with a new method for quickly testing cell samples for the presence of HPV.
More Related Videos
13:41Use of Interferon-γ Enzyme-linked Immunospot Assay to Characterize Novel T-cell Epitopes of Human Papillomavirus
Published on: March 8, 2012
07:54Surface-enhanced Resonance Raman Scattering Nanoprobe Ratiometry for Detecting Microscopic Ovarian Cancer via Folate Receptor Targeting
Published on: March 25, 2019
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...