Related Experiment Video
Updated: May 20, 2026

Polytetrafluoroethylene (PTFE) as a Suture Material in Tendon Surgery
Published on: October 6, 2022
Comparison of a multifilament stainless steel suture with FiberWire for flexor tendon repairs--an in vitro
E McDonald1, J A Gordon, J M Buckley
1UCSF/SFGH Orthopaedic Trauma Institute, University of California-San Francisco, CA, USA.
Abstract:
Our goal was to investigate and compare the mechanical properties of multifilament stainless steel suture (MFSS) and polyethylene multi-filament core FiberWire in flexor tendon repairs. Flexor digitorum profundus tendons were repaired in human cadaver hands with either a 4-strand cruciate cross-lock repair or 6-strand modified Savage repair using 4-0 and 3-0 multifilament stainless steel or FiberWire. The multifilament stainless steel repairs were as strong as those performed with FiberWire in terms of ultimate load and load at 2 mm gap. This study suggests that MFSS provides as strong a repair as FiberWire. The mode of failure of the MFSS occurred by the suture pulling through the tendon, which suggests an advantage in terms of suture strength.