Related Experiment Video
Updated: May 20, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Determination of Se using a solid-phase micro-extraction device coupled to a graphite furnace and detection by gas
Elidiane Gomes da Silva1, Fabio Augusto, Marco Aurélio Zezzi Arruda
1National Institute of Science and Technology for Bioanalytics and Spectrometry, Sample Preparation and Mechanization Group (GEPAM), Institute of Chemistry - University of Campinas (UNICAMP), P.O. Box 6154, 13083-970 Campinas, SP, Brazil.
Abstract:
A solid-phase micro-extraction (SPME) method using an SPME fiber device and graphite furnace (GF) for extracting Se compounds was proposed. Various factors affecting the derivatization and extraction of Se(IV) by SPME-GF were evaluated, including the effect of acid (type and concentration), the concentration of the derivatizing agent, the derivatization temperature, the extraction and derivatization times and the extraction temperature. After optimizing these conditions, the quantification of Se(IV) was performed by Gas Chromatography-Mass Spectrometry (GC-MS). The limit of detection was 0.37 μg L(-1) for Se(IV). The method was successfully applied to the total Se determination in certified reference materials (BCR-414 and SRM 1643e). A recovery of 97% was obtained for water (SRM 1643e). After microwave oven decomposition and the reduction of selenium using a mixture of 2 mol L(-1) HCl and 1% (w/v) KBr, a recovery of 101% and a relative standard deviation of 3.5% were attained for plankton (BCR-414). The SPME-GF method combined with GC-MS was also applied to the determination of the total selenium in a drug sample (selenium chelate).
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...