Related Experiment Video
Updated: May 20, 2026

Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
Elimination of nitrogen interference during online oxygen isotope analysis of nitrogen-doped organics using the
William M Hagopian1, A Hope Jahren
1Department of Geology and Geophysics, University of Hawaii, Honolulu, HI 96822, USA. william8@hawaii.edu
Rationale:
Accurate online analysis of the δ(18)O values of nitrogen-bearing organic compounds is of interest to several emergent fields, including ecology, forensics and paleontology. During online analysis, high-temperature conversion (HTC) of nitrogen-bearing organics produces N(2) gas which creates isobaric interference with the isotopic measurement. Specifically, N(2) reacts with trace amounts of oxygen in the mass spectrometer source to form (14)N(16)O (m/z 30), which prevents accurate evaluation of the sample (12)C(18)O peak (m/z 30).
Methods:
We present an alternative system to the conventional HTC, which uses a nickel-catalyzed ("NiCat") reduction furnace to convert HTC-produced CO into CO(2), allowing for δ(18)O measurement using signal intensities at m/z 44 and 46.
Results:
This system yields identical δ(18)O values for nitrogen-doped and undoped sucrose and cellulose compounds up to molar yield ratios of N(2):CO = 0.22. In contrast, our conventional HTC system configured to factory recommendations with the stock gas chromatography (GC) column produced a discrepancy of ~5‰ between nitrogen-doped and undoped samples.
Conclusions:
Because of its ability to eliminate isobaric interference, the NiCat system is a viable alternative to conventional HTC for δ(18)O measurement, and can be constructed from relatively inexpensive and readily available materials. As an additional advantage, the CO(2) analyte produced by NiCat may be cryofocused, to allow for oxygen-isotope determinations on very small amounts of sample substrate.
Related Concept Videos
Inorganic Nitrogen Assimilation
Preparation of Amines: Reduction of Oximes and Nitro Compounds
Though catalytic hydrogenation can reduce nitrobenzenes, the reduction is nonselective in the presence of other functional groups. For instance, if nitrobenzene contains an aldehyde group,...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2° Amines to N-Nitrosamines: Reaction with NaNO2

