Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Design of compensation coils for EMI suppression in magnetostrictive linear position sensors
Yongjie Zhang1, Weiwen Liu, Jinfeng Yang
1School of Electronic, Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
Abstract:
This paper presents recent development on magnetostrictive linear position sensors (MLPS). A new compensation coil structure improves the EMI suppression and accuracy considerably. Furthermore, experimental results indicate that the new structure can improve the accuracy to ± 0.13 mm nearly double the ± 0.2 mm obtained with traditional structures. As another design continuation after the differential waveguide structure, this new structure is a practical and reliable implementation technique for the commercialization of MLPS.
More Related Videos
Related Concept Videos
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Magnetic Field Due to Two Straight Wires
Magnetic Field Due To A Thin Straight Wire
Mutual Inductance
When two circuits carrying time-varying currents are close to one another, the magnetic flux through each circuit varies because of the changing current in the other circuit. Consequently, an emf is induced in each circuit by the changing current in the other. Therefore, this type of emf is called...
Magnetic Field Of A Current Loop
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...