Relation between beat-to-beat QT interval variability and T-wave amplitude in healthy subjects
Muhammad A Hasan1, Derek Abbott, Mathias Baumert
1School of Electrical and Electronic Engineering Centre for Heart Rhythm Disorders, The University of Adelaide, Adelaide, SA, Australia.
Objectives:
Elevated beat-to-beat QT interval variability (QTV) has been associated with increased cardiovascular morbidity and mortality.The aim of this study was to investigate interlead differences in beat-to-beat QTV of 12-lead ECG and its relationship with the T wave amplitude.
Methods:
Short-term 12-lead ECGs of 72 healthy subjects (17 f, 38 ± 14 years; 55 m, 39 ± 13 years) were studied. Beat-to-beat QT intervals were extracted separately for each lead using a template matching algorithm. We calculated the standard deviation of beat-to-beat QT intervals as a marker of QTV as well as interlead correlation coefficients. In addition, we measured the median T-wave amplitude in each lead.
Results:
There was a significant difference in the standard deviation of beat-to-beat QT intervals between leads (minimum: lead V(3) (2.58 ± 1.36 ms), maximum: lead III (7.2 ± 6.4 ms), ANOVA: P < 0.0001). Single measure intraclass correlation coefficients of beat-to-beat QT intervals were 0.27 ± 0.18. Interlead correlation coefficients varied between 0.08 ± 0.33 for lead III and lead V(1) and 0.88 ± 0.09 for lead II and lead aVR. QTV was negatively correlated with the T-wave amplitude (r =-0.62, P < 0.0001). There was no significant affect of mean heart rate, age or gender on QT variability (ANOVA: P > 0.05).
Conclusions:
QTV varies considerably between leads in magnitude as well as temporal patterns. QTV is increased when the T wave is small.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Dysrhythmias III: Characteristics of Dysrhythmias
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...